Bouyer Leroux high precision masonry clay unitsDurability of Biobric and BGV Load bearing units |
![]() |
Biobric 37.5, Biobric 30 and the BGV units are classified by the EN/BS771.1 Standard as LD (low density) protected units, category 1 (compressive strength probability of failure max. 5%). The Standard and the CE Mark require to declare the following parameters related to durability: Resistance to Soluble Salts
Freeze/Thaw Resistance Not loose > 1% mass |
||
Biobric and BGV units comply with the above and do not suffer any alteration to their characteristics after testing. They are therefore suitable to be adopted in cold climates and high exposure zones. |